AIR CONDITIONER FOR
SERVER ROOMS
The compact precision air conditioner of the BP3 series provides precise temperature and humidity conditions in the server room in accordance with Russian and international standards CH 512-78, ASHRAE.
Optimal indoor climate conditions created by BP3 air conditioners help improve the performance of computer equipment and reduce the number of breakdowns.
Precision air conditioners BP3 for a server room:
-installed without a raised floor, with dimensions of 30cm x 100cm x 200cm, freely placed between server racks.
- compatible with security, control and guaranteed power supply systems, with racks and telecommunication cabinets from any manufacturer.
- support the built-in server cooling system when room temperature deviations are above critical.
-protect computing equipment from the accumulation of static electricity, condensation and corrosion.
Russian standard SN 512-78. Microclimate requirements:
• Air temperature - 20°±2°C (no more than 25°C). When supplying cooled air directly to devices (racks with equipment), its inlet temperature should not be lower than 14 °C.
• Relative air humidity - 20-70% (no more than 75% in the cold period, in the warm period for 25 °C - no more than 65%, for 24 °C and below - no more than 70%).
• Air flow speed - 0.2 m/s (no more than 0.3 m/s for cold periods, 0.5 m/s for warm periods).
• The dust level in the server room is 0.75 mg/m3. with particle sizes of no more than 3 microns (atmospheric dust, soot, smoke); in data center premises - 2 mg/m3.
Ensuring maximum efficient operation of the refrigeration circuit, controlling air supply and maintaining pressure. They are equipped with displays of various sizes and functionality. Compatible with protocols (Modbus, SNMP, Lonworks, Bacnet, etc.) and BMS systems.
Accurate measurement of microclimate parameters, transfer of data to an integrated controller with subsequent adjustment of humidity levels, air temperature and leakage alarm.
Low temperature air conditioning kit ensures continuous operation of IT infrastructure in harsh climate conditions.
The copper-aluminum evaporator heat exchanger has a large heat exchange area. The evaporator is equipped with a stainless steel tray with a flexible pipe for collecting drips.
Electronically commutated fans allow variable speed control and a wide range of air flow and static pressure. The built-in electronic control system optimizes air flow distribution.
Effective cleaning of the server room from dust and small particles, creating comfortable breathing for humans. Various options with higher levels of filtration are available.
In case of power surges in the network, the VYBOS air conditioner restarts automatically. To avoid the adverse effects of low-quality voltage in the server room, we recommend purchasing voltage stabilizers or
uninterruptible power supplies.