Air conditioners are designed to continuously maintain the temperature, humidity and volume and purity of air flow .
ROW unit is a multi-split system, designed for high density CED system
HIGH TECHNOLOGY EQUIPMENT VYBOS
DEVELOPMENT AND MANUFACTURE
Главная страница   Solutions   Conditioning of data centers

 

 

 

AIR CONDITIONING
DATA CENTERS

The VYBOS precision air conditioning system is designed for data centers in the isolation strategy of hot or cold corridors, as well as for structures with a closed cooling cycle.
The VYBOS solution is suitable for data processing centers of any power (from 4 kW and above 14 kW) per rack.

ADVANTAGES OF THE EQUIPMENT - Optimal distribution of air flows, elimination of local overheating zones in the data center.
- Reduction of data center electricity consumption due to energy-efficient equipment components.
- Easy integration and full compatibility with data center infrastructure components: uninterruptible power supply, surveillance, fire extinguishing, power distribution, etc.
-Data center support in conditions of high and low outdoor temperatures (from -60 C to +50 C)

EQUIPMENT FOR DATA CENTERS
Find out the price
ENERGY-EFFICIENT COMPONENTS
FOR DATA CENTER COOLING
CONTROLLERS
Ensuring maximum efficient operation of the refrigeration circuit, controlling air supply and maintaining pressure. They are equipped with displays of various sizes and functionality. Compatible with protocols (Modbus, SNMP, Lonworks, Bacnet, etc.) and BMS systems.
ADDITIONAL TEMPERATURE AND HUMIDITY SENSORS, WATER LEAKS (POINT AND TAPE)
Accurate measurement of microclimate parameters, transfer of data to an integrated controller with subsequent adjustment of humidity levels, air temperature and leakage alarm.
LOW TEMPERATURE SETS: до -60°С 
Low temperature air conditioning kit ensures continuous operation of IT infrastructure in harsh climate conditions.
HEAT EXCHANGER
The copper-aluminum evaporator heat exchanger has a large heat exchange area. The evaporator is equipped with a stainless steel tray with a flexible pipe for collecting drips.
EC FANS WITH ELECTRONIC CONTROL
Electronically commutated fans allow variable speed control and a wide range of air flow and static pressure. The built-in electronic control system optimizes air flow distribution.
AIR FILTERS OF DIFFERENT CLASSES
Effective cleaning of the server room from dust and small particles, creating comfortable breathing for humans. Various options with higher levels of filtration are available.
AUTOMATIC RESTART FUNCTION
In case of power surges in the network, the VYBOS air conditioner restarts automatically. To avoid the adverse effects of low-quality voltage in the server room, we recommend purchasing voltage stabilizers or uninterruptible power supplies.
REDUCE
ENERGY CONSUMPTION
WITH ENERGY-EFFICIENT SOLUTIONS